Q3 Automatic Transfer Switch (hereinafter referred to as ATS), it is suitable for the power supply system of AC 50Hz, rated voltag f 400V, rated current of 63A and below. Choice and conversion between two power supply according to the needs. ATS have protection functions of overload, short circuit, under-voltage, but also have functions of fire, double breaking and output closing signal. Particularly applicable to the lighting lines in office buildings, shopping malls, banks, high-rise buildings and other places with needs of the fire.
Q3 Automatic Transfer Switch (hereinafter referred to as ATS), it is suitable for the power supply system of AC 50Hz, rated voltag f 400V, rated current of 63A and below. Choice and conversion between two power supply according to the needs. ATS have protection functions of overload, short circuit, under-voltage, but also have functions of fire, double breaking and output closing signal. Particularly applicable to the lighting lines in office buildings, shopping malls, banks, high-rise buildings and other places with needs of the fire.
Q3 Automatic Transfer Switch complies with GB / T14048.11 standard.
Models and Specifications
Normal operating conditions and installation conditions
● The altitude of the installation site should not exceed 2000m.
● Ambient air temperature
Ambient air temperature does not exceed the upper limit is +40℃; the average ambient air temperature in 24h does not exceed +35℃. The ambient air temperature lower limit is not less than -5 ℃.
● Atmospheric conditions
○ Humidity
At the maximum temperature of +40℃, the air relative humidity is less than 50%, there is a higher relative humidity allowed at lower temperatures, for example, up to 90% at 20℃. Special measures should be taken for gel that is occasionally generated due to changes of humidity.
○ Pollution degree: 3
● Installation conditions
Installed in the place without shock and invasion of rain and snow ; the upper terminal connect to the power side, the lowr terminal connect to the load side; the inclination between products and vertical plane is not more than 5°.
● Installation category: Ⅲ
● The external magnetic field near the installation site does not exceed 5 times the geomagnetic field in any direction.
Technical parameter
Basic parameters of Q3 Automatic Transfer Switch see Table 1
Product
performance parameters
Meet the
standards
GB/T
14048.11
ATS
class
CB class
Use
categories
AC-33iB
Rated
operating voltage Ue
AC230V-400V
Rated
operating frequency
50Hz/60Hz
Rated
operating current Ie
6A, 10A,
16A, 20A, 25A, 32A, 40A, 50A 63A
Switching
control voltage
AC230V
Rated
insulation voltage Ui
AC690V
Conversion
operation time
≤3s(Not
adjustable, the factory has been adjusted)
Life
Electrical
life
1500
times
Mechanaical
life
6000
times
Rated
short-time making capacity Icm
7.5kA
Rated
short-time breaking capacity Icn
5kA
Basic parameters of terminal type and intelligent type of Q3 Automatic Transfer Switch in Table 2
Product
model
Common
type
Intelligent
type
Installation
method
Integral
type
Integral
type
Operation
method
Automatic
and manual
Automatic manual and
double breaking
Monitoring
function
Phase
failure detection
Common power supply
three-phase undervoltage,
lack phase and phase
failure detection
Conversion
method
Automatic change and
automatic recovery
Automatic change and
automatic recovery
Fire
linkage control
No
DC12-24V input
double breaking
(Automatic fire cut-off function)
Display
function
LED
light
LED
light
Outline and mounting dimensions
Size
Model and specification
Outline
dimensions
Installation
dimensions
L
W
H
L1
W1
Φd
Four-pole
switch
220
132
120
200
120
5
Installation
Connection wire (cable) for ATS uses single core polyvinyl chloride (PVC) insulated copper wire or equivalent copper bar, the sectional area is selected according to the table 4.
Rated
current In(A)
6
10
16 20
25
32
40 50
63
Sectional area of wire or copper bar mm²
1.0
1.5
2.5
4.0
6.0
10
16
Wiring diagram of ATS
Wiring diagram of four-pole switch
Wiring diagram of three-pole switch
Wiring diagram of ATS output terminals
Wiring diagram of commom type output terminals
Wiring diagram of intelligent type output terminals
Ordering Information
Users must specify when ordering:
7.1 Name and type of Q3 Automatic Transfer Switch;
7.2 The rated current (A) of Q3 Automatic Transfer Switch;
7.3 Poles (four-pole, the ATS is three-phase four-wire system when the customer does not indicate);
7.4 Controller type of Q3 Automatic Transfer Switch;
7.5 Quantity.
7.6 Customer requirements for Miniature Circuit Breakers DZ47 or C65
For example: ordering Q3 Automatic Transfer Switch, three-pole, rated current of 6A, common type, the number of 100 units. Can be written as: Q3-63 / 3P 6A 50 units.
Order Q3 Automatic Transfer Switch, four-pole, rated current of 63A, intelligent type, miniature circuit breakers require 50 DZ47D type. Can be written as: Q3-63 / 4P 63A DZ47D 100 units.
Hot Tags: Q3 Automatic Transfer Switch, China, Manufacturer, Supplier, Factory
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies.
Privacy Policy